skip to main content
Language:
Search Limited to: Search Limited to: Resource type Show Results with: Show Results with: Search type Index

A novel biosensor for the detection of organophosphorus -FL variant

Applied microbiology and biotechnology, 2021-01, Vol.105 (1), p.389 [Peer Reviewed Journal]

COPYRIGHT 2021 Springer ;ISSN: 0175-7598 ;EISSN: 1432-0614 ;DOI: 10.1007/s00253-020-11008-w

Full text available

Citations Cited by
  • Title:
    A novel biosensor for the detection of organophosphorus -FL variant
  • Author: Jain, Monika ; Yadav, Priyanka ; Joshi, Bhavana ; Joshi, Abhijeet ; Kodgire, Prashant
  • Subjects: Biosensors ; Innovations
  • Is Part Of: Applied microbiology and biotechnology, 2021-01, Vol.105 (1), p.389
  • Description: Indiscriminate use of organophosphorus (OP)-based insecticides is a great concern to human health because of bioaccumulation-induced health hazards. Potentially fatal consequences and limited treatment methods of OP poisoning necessitate the need for the development of reliable, selective, cost-effective, and sensitive methods of OP detection. To tackle this issue, the development of effective devices and methods is required to sensitively detect as well as degrade OPs. Enzymatic sensor systems have gained popularity due to high catalytic activity, enhanced detection limits, and high sensitivity with the environmentally benign operation. Organophosphorus acid anhydrolase (OPAA) from Alteromonas sp. JD6.5 is capable of hydrolyzing the P-F, P-O, P-S, and P-CN bonds, in OPs, including nerve agents of the G/V-series. Several mutants of OPAA are reported which have greater activity against various OPs. In this study, recombinant expression of the OPAA-FL variant in Escherichia coli was performed, purified, and subsequently tested for activity against ethyl paraoxon. OPAA-FL variant showed its optimum activity at pH 8.5 and 50 °C. Colorimetric and fluorometric assays were used for estimation of ethyl paraoxon based on p-nitrophenol and fluorescein isothiocyanate (FITC) fluorescence intensity, respectively. Colorimetric and fluorometric assay estimation indicates that ethyl paraoxon can be estimated in the linear range of 0.01 to 1 mM and 0.1 to 0.5 mM, with LOD values 0.04 mM and 0.056 mM, respectively. Furthermore, the OPAA-FL variant was immobilized into alginate microspheres for colorimetric detection of ethyl paraoxon and displayed a linear range of 0.025 to 1 mM with a LOD value of 0.06 mM. Key points * Biosensing of paraoxon with purified and encapsulated OPAA-FL variant. * Colorimetric and fluorometric biosensing assay developed using OPAA-FL variant for paraoxon. * First report on alginate encapsulation of OPAA-FL variant for biosensing of paraoxon. Graphical abstract
  • Publisher: Springer
  • Language: English
  • Identifier: ISSN: 0175-7598
    EISSN: 1432-0614
    DOI: 10.1007/s00253-020-11008-w
  • Source: ProQuest Central

Searching Remote Databases, Please Wait