Transcatheter Valve-in-Valve Implantation in an Aortic Bioprosthesis With Severe Regurgitation and a Challenging Aortic Anatomy

JACC. Case reports, 2022-03, Vol.4 (6), p.336-342 [Peer Reviewed Journal]

2022 The Authors. ;2022 The Authors 2022 ;ISSN: 2666-0849 ;EISSN: 2666-0849 ;DOI: 10.1016/j.jaccas.2021.12.025 ;PMID: 35495559

Full text available

Citations Cited by
  • Title:
    Transcatheter Valve-in-Valve Implantation in an Aortic Bioprosthesis With Severe Regurgitation and a Challenging Aortic Anatomy
  • Author: Marchese, Alfredo ; Tarantini, Giuseppe ; Tito, Antonio ; Resta, Fabrizio ; Paparella, Domenico ; Speziale, Giuseppe
  • Subjects: Case Report
  • Is Part Of: JACC. Case reports, 2022-03, Vol.4 (6), p.336-342
  • Description: Valve-in-valve transcatheter aortic valve replacement for failing surgical bioprosthetic valves becomes troublesome if a stiff vascular prosthesis replaces the ascending aorta. We report the off-label use of a new transcatheter aortic valve for treatment of a patient with a bioprosthetic valve with central regurgitation, a horizontal aorta, and kinking of the aortic prosthesis. ( ).