skip to main content
Language:
Search Limited to: Search Limited to: Resource type Show Results with: Show Results with: Search type Index

Differences between the Results Assessed by Slit Lamp Examination and Anterior Segment Photography in Terms of Cataract Grading

Daihan angwa haghoi jabji, 2023-11, Vol.64 (11), p.1009-1013 [Peer Reviewed Journal]

ISSN: 0378-6471 ;EISSN: 2092-9374 ;DOI: 10.3341/jkos.2023.64.11.1009

Full text available

Citations Cited by
  • Title:
    Differences between the Results Assessed by Slit Lamp Examination and Anterior Segment Photography in Terms of Cataract Grading
  • Author: Kim, Woojin ; Yoon, Sumin ; Kim, Dong Hyun ; Eom, Youngsub ; Song, Jong Suk
  • Is Part Of: Daihan angwa haghoi jabji, 2023-11, Vol.64 (11), p.1009-1013
  • Description: Purpose: We compared the cataract grades with slit lamp examination and anterior segment photography using the Lens Opacities Classification System (LOCS) III criteria. We also explored the effect of a yellow filter on the photographic results.Methods: Eighty eyes with cataracts were examined by three inspectors (1, 2, and 3). Anterior segment photographs taken by inspector 1 were divided into two groups depending on whether cortical opacity or nuclear sclerosis predominated. In each group, the cataract grades determined by inspector 1 on slit lamp examination and anterior segment photography were compared. Also, after randomly assigning the anterior segment photographs taken by inspector 1 to inspectors 2 and 3, the cataract grades of these photographs were compared to the grades of photographs taken by all inspectors using a yellow filter.Results: The average cortical opacity evaluated by inspector 1 on slit lamp examination (3.48 ± 0.91) was significantly higher than that apparent on anterior segment photographs (2.35 ± 0.77) (p < 0.001). In the photographs, the average cortical opacity when a yellow filter was used was significantly higher for both inspectors 1 (p < 0.001) and 2 (p = 0.022) than when the filter was absent. The average extent of nuclear sclerosis evaluated by inspector 1 on slit lamp examination (4.08 ± 0.94) was significantly higher than that of anterior segment photography (3.73 ± 1.24) (p = 0.042).Conclusions: Cataract evaluation via anterior segment photography underestimates the extent of damage compared to direct slit lamp examination. However, use of a yellow filter during photography aids cataract evaluation, especially cortical opacity.
  • Language: English
  • Identifier: ISSN: 0378-6471
    EISSN: 2092-9374
    DOI: 10.3341/jkos.2023.64.11.1009
  • Source: KoreaMed Open Access

Searching Remote Databases, Please Wait