skip to main content
Language:
Search Limited to: Search Limited to: Resource type Show Results with: Show Results with: Search type Index

User Influence on Indoor Aerosol Model Calibration

Aerosol and Air Quality Research, 2011-06, Vol.11 (3), p.309-314 [Peer Reviewed Journal]

ISSN: 1680-8584 ;EISSN: 2071-1409 ;DOI: 10.4209/aaqr.2010.12.0104

Full text available

Citations Cited by
  • Title:
    User Influence on Indoor Aerosol Model Calibration
  • Author: Hussein, T ; Molgaard, B ; Hameri, K
  • Subjects: Aerosol models ; Aerosol particles ; Aerosols ; Air quality ; Atmospheric pollution ; Numerical simulations ; Particulates ; Pollutant deposition ; Simulation ; Velocity ; Ventilation
  • Is Part Of: Aerosol and Air Quality Research, 2011-06, Vol.11 (3), p.309-314
  • Description: Calibration, or in other words "validation", of complex indoor aerosol models that simulate the dynamic behavior of particle number size distributions are often assumed to solely depend on the characteristics of the model and its setup. The user influence is rarely mentioned in that regard. This paper shows, with a simple exercise, the user influence on the calibration of an indoor aerosol model. It is also shown that a reasonable model simulation was achieved with a different understanding of the system modeled and several input parameter values. We utilized a single compartment and size-resolved indoor aerosol model approach to be calibrated against a model room. This kind of simple indoor aerosol models is very common in the literature and widely used in the analysis of indoor-to-outdoor relationship of aerosol particles. The input parameters for such indoor aerosol models are: outdoor particle number size distributions, indoor domain geometries, ventilation rate, penetration factor, and friction velocity (or deposition rate onto indoor surfaces). For simplicity, we considered the penetration factor and friction velocity are the only unknown input parameters to be chosen freely by the user so that the model is calibrated. We made it clear by this study that a user can influence the input parameter values significantly. Even though this suggests different sets of input parameter values can be valid for a model calibration, the model simulation differences between different calibration results remained within 1%. This implies that it is more challenging to calibrate a complex indoor aerosol model that requires many input parameters.
  • Publisher: 社團法人台灣氣膠研究學會
  • Language: English
  • Identifier: ISSN: 1680-8584
    EISSN: 2071-1409
    DOI: 10.4209/aaqr.2010.12.0104
  • Source: DOAJ Directory of Open Access Journals

Searching Remote Databases, Please Wait