skip to main content
Language:
Search Limited to: Search Limited to: Resource type Show Results with: Show Results with: Search type Index

100 cases of three-piece Inflatable Penile Prosthesis with new scrotal pump: Evaluation of 3 specialised centres

Archivos españoles de urología, 2015-05, Vol.68 (4), p.416-423 [Peer Reviewed Journal]

ISSN: 0004-0614 ;EISSN: 1576-8260 ;PMID: 26033761

Full text available

Citations Cited by
  • Title:
    100 cases of three-piece Inflatable Penile Prosthesis with new scrotal pump: Evaluation of 3 specialised centres
  • Author: Garrido-Abad, Pablo ; Rosselló-Barbará, Mariano ; Sabino-Galdona, José ; Fernández-Arjona, Manuel ; Rosselló-Gayá, Mariano
  • Subjects: Adult ; Aged ; Humans ; Male ; Middle Aged ; Penile Prosthesis ; Prosthesis Design ; Retrospective Studies ; Scrotum ; Young Adult
  • Is Part Of: Archivos españoles de urología, 2015-05, Vol.68 (4), p.416-423
  • Description: The aim is to assess our experience with new Coloplast Titan™ Inflatable Penile Prosthesis (IPP) with One-Touch Release (OTR) pump. Our 3 main focuses of attention will be prosthesis performance and patient and partner satisfaction in our first 100 cases in 3 specialised centres by 2 principal surgeons. Retrospective review was used to assess the Coloplast Titan™ OTR implant procedures/cases in our departments (from October 2009 to December 2012). The changes in Erection Function (EF), Intercourse Satisfaction (IS), overall satisfaction of the patient and partner were assessed by use of the following questionnaires: EF and IS domains of the International Index of Erectile Function (IIEF) and modified EDITS. Mean patient age (N = 100) was 54.2 years old (range: 20-77) with a mean length of follow-up of 21 months (range: 6-44). Mean length of prosthesis implanted was 18.6 cm (14-23.5). Only 3% of patients showed complications requiring surgical exploration. Good prosthesis performance was assessed in 99 patients (99%). Differences in the IIEF-EF and IIEF-IS domain before and after surgery were +16.8 and +6.4 respectively. Patient and partner overall satisfaction were 90% and 84% respectively in modified EDITS. The average number of postoperative teaching sessions needed to teach the patient how to operate the device was 1.28 (1-4). The Coloplast Titan™ OTR IPP was easy to implant, inflate, and deflate with high levels of EF improvement, patient and partner satisfaction. A small number of postoperative teaching sessions were required for the patient to properly operate the device.
  • Publisher: Spain
  • Language: Spanish
  • Identifier: ISSN: 0004-0614
    EISSN: 1576-8260
    PMID: 26033761
  • Source: MEDLINE