skip to main content
Language:
Search Limited to: Search Limited to: Resource type Show Results with: Show Results with: Search type Index

Fracture resistance and failure mode of layered translucent zirconia with different crown designs

Dental Materials Journal, 2021, pp.2021-051

2021 The Japanese Society for Dental Materials and Devices ;ISSN: 0287-4547 ;EISSN: 1881-1361 ;DOI: 10.4012/dmj.2021-051

Full text available

Citations Cited by
  • Title:
    Fracture resistance and failure mode of layered translucent zirconia with different crown designs
  • Author: AL-QAYSI, Saif H. ; SALEH, Abdul Rahman MOHAMMED ; EL-DAMANHOURY, Hatem M.
  • Subjects: Fully veneered zirconia ; Monolithic zirconia ; Partially veneered zirconia ; Translucent zirconia
  • Is Part Of: Dental Materials Journal, 2021, pp.2021-051
  • Description: This study investigated the impact of different veneering design on the fracture resistance and failure mode of layered translucent zirconia crowns, compared to the full monolithic zirconia crowns. Ninety crowns with different designs were divided into six groups (n=15); one fully contoured monolithic crown (FMC), one fully veneered with porcelain (FVC), or four partially veneered designs. All crowns were thermo-cycled, and then loaded to failure in a universal testing machine. The fracture resistance (N) and fracture modes were assessed. One-way ANOVA was performed followed by Tukey’s multiple comparison (α<0.05). Results demonstrated that all the tested partially veneered designs exhibited enhanced fracture resistances and were comparable to that of the full-contour monolithic translucent zirconia crowns.
  • Publisher: The Japanese Society for Dental Materials and Devices
  • Language: English
  • Identifier: ISSN: 0287-4547
    EISSN: 1881-1361
    DOI: 10.4012/dmj.2021-051
  • Source: Alma/SFX Local Collection

Searching Remote Databases, Please Wait